	 pdf
 pdf
		
	
		| Model | No. of wells / comb(in ready-to-use system) | Max no. of wells/ comb available(Check table below) | Gel size(w x l) cm | Max. no. of comb | Buffer requi | For DNA and Protein separation | For RNA separation | With cool | Reco | 
| SLEEK | 10 | 20 | 7 x 5 | 2 | 270 mL | Yes | No | No | ELECTRAGEL - 100 300V, 100mA | 
| 7 x 10* | 4 | ||||||||
| 7 x 15 | 6 | ||||||||
| SLEEK | 10 | 20 | 7 x 5 | 2 | 270 mL | Yes | Yes | No | ELECTRAGEL - 100 300V, 100mA | 
| 7 x 10* | 4 | ||||||||
| 7 x 15 | 6 | ||||||||
| Trays marked with an * are supplied as part of the ready-to-use system | |||||||||
| GELMARINER | 15 | 30 | 10 x 5 | 2 | 400 mL | Yes | No | No | ELE | 
| 10 x 10 | 4 | ||||||||
| 10 x 15* | 6 | ||||||||
| 10 x 20 | 8 | ||||||||
| GELMARINER-R | 15 | 30 | 10 x 5 | 2 | 400 mL | Yes | Yes | No | ELE | 
| 10 x 10 | 4 | ||||||||
| 10 x 15* | 6 | ||||||||
| 10 x 20 | 8 | ||||||||
| GELMARINER-RC | 15 | 30 | 10 x 5 | 2 | 400 mL | Yes | Yes | Yes | ELE | 
| 10 x 10 | 4 | ||||||||
| 10 x 15* | 6 | ||||||||
| 10 x 20 | 8 | ||||||||
| Trays marked with an * are supplied as part of the ready-to-use system | |||||||||
| GREY | 24 | 45 | 15 x 5 | 2 | 1000 mL | Yes | No | No | ELECTRAPRIME 300V, 400mA | 
| 15 x 10 | 4 | ||||||||
| 15 x 15 | 6 | ||||||||
| 15 x 20* | 8 | ||||||||
| 15 x 25 | 10 | ||||||||
| GREY | 24 | 45 | 15 x 5 | 2 | 1000 mL | Yes | Yes | No | ELECTRAPRIME 300V, 400mA | 
| 15 x 10 | 4 | ||||||||
| 15 x 15 | 8 | ||||||||
| 15 x 20* | 8 | ||||||||
| 15 x 25 | 10 | ||||||||
| GREY | 24 | 45 | 15 x 5 | 2 | 1000 mL | Yes | Yes | Yes | ELECTRAPRIME 300V, 400mA | 
| 15 x 10 | 4 | ||||||||
| 15 x 15 | 8 | ||||||||
| 15 x 20* | 8 | ||||||||
| 15 x 25 | 10 | ||||||||
| GREY | 24 | 45 | 15 x 5 | 2 | 900 mL | Yes | No | No | ELECTRAPRIME 300V, 400mA | 
| 15 x 10 | 4 | ||||||||
| Trays marked with an * are supplied as part of the ready-to-use system | |||||||||
| SUB | 36 | 70 | 23 x 5 | 2 | 1800 mL | Yes | No | No | ELECTRACOMET 200V, 500mA | 
| 23 x 10 | 4 | ||||||||
| 23 x 15 | 6 | ||||||||
| 23 x 20* | 8 | ||||||||
| 23 x 25 | 11 | ||||||||
| SUB | 36 | 70 | 23 x 5 | 2 | 1800 mL | Yes | Yes | No | ELECTRACOMET 200V, 500mA | 
| 23 x 10 | 4 | ||||||||
| 23 x 15 | 6 | ||||||||
| 23 x 20* | 8 | ||||||||
| 23 x 25 | 11 | ||||||||
| SUB | 36 | 70 | 23 x 5 | 2 | 1800 mL | Yes | Yes | Yes | ELECTRACOMET 200V, 500mA | 
| 23 x 10 | 4 | ||||||||
| 23 x 15 | 6 | ||||||||
| 23 x 20* | 8 | ||||||||
| 23 x 25 | 11 | ||||||||
| SUB | 36 | 70 | 23 x 5 | 2 | 1500 mL | Yes | No | No | ELECTRACOMET 200V, 500mA | 
| 23 x 10 | 4 | ||||||||
| 23 x 15 | 6 | ||||||||
| Trays marked with an * are supplied as part of the ready-to-use system | |||||||||
| GREY | 54 | 92 | 30 x 5 | 2 | 2200 mL | Yes | Yes | No | ELEC | 
| 30 x 10 | 4 | ||||||||
| 30 x 15 | 6 | ||||||||
| 30 x 20 | 8 | ||||||||
| 30 x 25 | 10 | ||||||||
| 30 x 30* | 14 | ||||||||
| GREY | 54 | 92 | 30 x 5 | 2 | 2200 mL | Yes | Yes | Yes | ELEC | 
| 30 x 10 | 4 | ||||||||
| 30 x 15 | 6 | ||||||||
| 30 x 20 | 8 | ||||||||
| 30 x 25 | 10 | ||||||||
| 30 x 30* | 14 | ||||||||
| GREY | 54 | 92 | 30 x 5 | 2 | 2000 mL | Yes | Yes | No | ELECTRACOMET 200V, 500mA | 
| 30 x 10 | 4 | ||||||||
| 30 x 15 | 6 | ||||||||
| Trays marked with an * are supplied as part of the ready-to-use system | |||||||||
| Ligo | 4 | 4 | 2.8 x 8.5 | 1 | NA | Yes | Yes | NA | NA | 
| Refer to Komet  for single cell electrophoresis in the 
									Special Equipment section 	
		
		and CA strip and slide for paper and slide electrophoresis section | |||||||||
| Sleeksub/Gelmariner/Greyhound/Greywhale | Gelmariner/Greyhound/Greywhale | Greyhound/Greywhale | Greywhale | ||||||||||||||||||||||
| Tray of width | |||||||||||||||||||||||||
| 3c | 7cm | 1 | 1 | 3 | Traylength | No. ofcom | 4 w | 10 w | 15 w | 20 w | 10 w | 16 w | 21 w | 24 w | 30 w | 17 w | 24 w | 28 w | 33 w | 36 w | 45 w | 33 w | 54 w | 65 w | 92 w | 
| 30 c | 25 c | 20 c | 15 c | 10 c | 5 c | 1 | 4 | 10 | 15 | 20 | 10 | 16 | 21 | 24 | 30 | 17 | 24 | 28 | 33 | 36 | 45 | 33 | 54 | 65 | 92 | 
| 2 | 8 | 20 | 30 | 40 | 20 | 32 | 42 | 48 | 60 | 34 | 48 | 56 | 66 | 72 | 90 | 66 | 108 | 130 | 184 | ||||||
| 3 | 12 | 30 | 45 | 60 | 30 | 48 | 63 | 72 | 90 | 51 | 72 | 84 | 99 | 108 | 135 | 99 | 162 | 195 | 276 | ||||||
| 4 | 16 | 40 | 60 | 80 | 40 | 64 | 84 | 96 | 120 | 68 | 96 | 112 | 132 | 144 | 180 | 132 | 216 | 260 | 368 | ||||||
| 5 | 50 | 75 | 100 | 50 | 80 | 105 | 120 | 150 | 85 | 120 | 140 | 165 | 180 | 225 | 165 | 270 | 325 | 460 | |||||||
| 6 | 60 | 90 | 120 | 60 | 96 | 126 | 144 | 180 | 102 | 144 | 168 | 198 | 216 | 270 | 198 | 324 | 390 | 552 | |||||||
| 7 | 70 | 112 | 147 | 168 | 210 | 119 | 168 | 196 | 231 | 252 | 315 | 231 | 378 | 455 | 644 | ||||||||||
| 8 | 80 | 128 | 168 | 192 | 240 | 136 | 192 | 224 | 264 | 288 | 360 | 264 | 432 | 520 | 736 | ||||||||||
| 9 | 153 | 216 | 252 | 297 | 324 | 405 | 297 | 486 | 585 | 828 | |||||||||||||||
| 10 | 170 | 240 | 280 | 330 | 360 | 450 | 330 | 540 | 650 | 920 | |||||||||||||||
| 11 | 187 | 264 | 308 | 363 | 396 | 495 | 363 | 594 | 715 | 10 | |||||||||||||||
| 12 | 396 | 643 | 780 | 11 | |||||||||||||||||||||
| 13 | 429 | 702 | 845 | 11 | |||||||||||||||||||||
| 14 | 462 | 756 | 910 | 12 | |||||||||||||||||||||
| Apparatus | Tray length(cm) | No. of slotsprovided instandard tray | Number of combsper tray | Running length | Possibility instandard trays | 
| Sleeksub/Gelmariner/Greyhound/Greywhale | 5 cm | 2 | 1 | 4.4 cm | Yes | 
| 2 | 2.1 cm | Yes | |||
| 10 cm | 4 | 1 | 9.4 cm | Yes | |
| 2 | 4.6 cm | Yes | |||
| 3 | 3.0 cm | Customization required# | |||
| 4 | 2.2 cm | Yes | |||
| Sleeksub/Gelmariner/Greyhound/Greywhale | 15 cm | 6 | 1 | 14.4 cm | Yes | 
| 2 | 7.1 cm | Yes | |||
| 3 | 4.7 cm | Yes | |||
| 4 | 3.5 cm | Customization required# | |||
| 5 | 2.8 cm | Customization required# | |||
| 6 | 2.3 cm | Yes | |||
| Gelmariner/Greyhound/Greywhale | 20 cm | 8 | 1 | 19.4 cm | Yes | 
| 2 | 9.6 cm | Yes | |||
| 3 | 6.4 cm | Customization required# | |||
| 4 | 4.7 cm | Yes | |||
| 5 | 3.8 cm | Customization required# | |||
| 6 | 3.1 cm | Customization required# | |||
| 7 | 2.6 cm | Customization required# | |||
| 8 | 2.3 cm | Yes | |||
| Greyhound/Greywhale | 25 cm | 10 | 1 | 24.4 cm | Yes | 
| 2 | 12.1 cm | Yes | |||
| 3 | 8.0 cm | Customization required# | |||
| 4 | 6.0 cm | Customization required# | |||
| 5 | 4.8 cm | Yes | |||
| 6 | 3.9 cm | Customization required# | |||
| 7 | 3.4 cm | Customization required# | |||
| 8 | 2.9 cm | Customization required# | |||
| 9 | 2.6 cm | Customization required# | |||
| 10 | 2.3 cm | Yes | |||
| 11 | 2.1 cm | Customization required# | |||
| Greywhale | 30 cm | 12 | 1 | 29.4 cm | Yes | 
| 2 | 14.6 cm | Yes | |||
| 3 | 9.7 cm | Yes | |||
| 4 | 7.2 cm | Yes | |||
| 5 | 5.8 cm | Customization required# | |||
| 6 | 4.8 cm | Yes | |||
| 7 | 4.1 cm | Customization required# | |||
| 8 | 3.5 cm | Customization required# | |||
| 9 | 3.1 cm | Customization required# | |||
| 10 | 2.8 cm | Customization required# | |||
| 11 | 2.5 cm | Customization required# | |||
| 12 | 2.3 cm | Yes | |||
| 13 | 2.1 cm | Customization required# | |||
| 14 | 2.0 cm | Customization required# | |||
| Apparatus | Tray length(cm) | No. of slotsprovided instandard tray | Number of combsper tray | Running length | Possibility instandard trays |