Search TechnoSource site  

      TechnoSource > Products > Illuminators > Gel Docs > GelViu series

    GelViu, gel documentation system

    GelViu is the versatile gel documentation system from TechnoSource.
    There are many optional features such as ports for gel manipulation,
    epi illumination, dual UV intensity & camera type
    GelViu systems provide a safe and sensitive way to view agarose
    gels, TLC plates, or PAGE gels

      Illuminated area size 20 (w) x 20 (l) cm
      With 8 tubes of 8 W each

      Cat. No. - TIGVB-082020
      Cat. No. is for the base without any accessories
        - GelViu , customisable,
        - Options between UVA, UVB, UVC or a combination of any 2
        - Switch for dual intensity of UV-light
        - Ports to manually access gel for band excision
        - Trans-illumination and epi-illumination for taking images
          in the UV and visible range
       - Various options of camera filters (Orange/ Red/ Green)
          compatible for use with different dyes



Download Gelviu series catalog pdf

      Build your GelViu by following this Selection Guide

Select your
GelViu base
This GeViu base allows multiple configurations of camera's, filters etc. GelViu
Window size 20 x 20 cm
# TIGVB-082020
Select your
Camera
Choose any one of the cameras based on the resolution you require DSLR, 18 MP
# TIGVS-CAMD18
DSLR, 24 MP
# TIGVS-CAMD24
Select your
Camera Filter
Choose the filter depending on the dye used for staining. One filter fits on the camera at a time. Filters can be manually changed if required. Green Camera filter
for DSLR, to view emission between 500-580 nm.
Suitable for SYBR Safe, SYBR Green, GelGreen

# TIGVS-CFILTG
Orange Camera filter
for DSLR, to view emission above 520 nm.
Suitable for EtBr, Acridine Orange

# TIGVS-CFILT0
Red Camera filter
for DSLR, to view emission above 550 nm.
Suitable for EtBr, GelRed, RedSafe

# TIGVS-CFILTR
Do you need a Port to access the gel Opt for the port if you need to adjust the gel or excise bands with the UV on. Port for accessing gel
made in the door of GelViu cabinet
# TIGVS-D0RPRT
No Port
Standard door
Select your
UV tubes
(for transillumination)
You can select 8 tubes of same UV type or 4 + 4 of two different UV types.
Choose based on application
UVA tube (8 W)
366 nm
For cloning/ sequencing,
Safe Handling,
Minimal DNA damage

# TIC0S-UA0801
UVB tube (8 W)
310 nm
Good for visualising,
Strong band visibility,
Higher DNA damage

# TIC0S-UB0801
UVC tube (8 W)
254 nm
Maximum excitation,
Strongest band visibility,
Highest DNA damage

# TIC0S-UC0801
Select your
UV filter
Select based on resolution required and cost effectiveness. If using UVB or UVC tubes, select the Optical Glass Bandpass Filter. Diffusing Plastic Filter
(only for UVA light)Good resolution, Low cost
# TIGVS-FP2020
Optical Glass Bandpass Filter
(for UVA, UVB or UVC light)Best resolution, High cost
# TIGVS-FG2020
Do you need an EPI white light Select this if your application requires photographing stained protein gels or for positioning the gel prior to image capture Yes
# TIGVS-EPWHLD
No
Do you need an EPI UV light Epi illumination can be opted for visualising TLC plates, gels or other applications. You can select upto any 2 of the UV lights Epi UVA light
366 nm
To view natural or derivatized fluorescence on TLC plates

# TIGVS-EPUVA8
Epi UVB light
310 nm
Good for visualising DNA. Not commonly used for TLC plates

# TIGVS-EPUVB8
Epi UVC light
254 nm
For visualising fluorescence on universal quenching indicator TLC plates
# TIGVS-EPUVC8
Select if Auto cut-off of UV light is needed? To prevent UV exposure, Auto cut-off shuts off UV when the door is opened. Do not select this if bands need to be excised with the door open. Yes
# TIGVS-D0R0FF
No
Do you need a UV shield For applications that involve excising bands from gel while the UV is on, a UV shield is recommended. The UV shield cannot be used with UV light shutting feature. Yes
# TIGVS-UVSHLD
No
Do you need a Hi-Low intensity control? >You can set the UV light intensity on low to prevent fading or bleaching of the DNA bands and for longer exposure times Yes
# TIGVS-UVHIL0
No




      Technical Specifications
FeatureGelViu
  Wavelength   366 nm/ 310 nm/ 254 nm
  Window size   20 (w) x 20 (l)
  Filter type   Diffusing plastic filter/ Optical bandpass filter
  Tube wattage (each tube)   8 W
  Number of Tubes   8
  Total tube wattage   64 W
  Safety Switch   Optional
  Binocular Chromafilter Eyepiece   No
  Operating temperature range   +10°C to +50°C
  Voltage input   230V rms, 50 Hz, single phase
  Voltage Variation (from nominal AC input voltage)   +5%, -5%
  Frequency   47Hz to 53Hz
  Transient suppression provided   No
  Component details
  Mains switches
  High Low switch
  Mains inlet
 
  Illuminated rocker switch
  Toggle switch
  IEC C14
  Insulation
~ between componenets & chassis
 
> 10Mohms @ 250DC
  Humidity tolerance   upto 95% (non condensing)
  Cooling by normal convection   Yes
  Dimensions of the body
[measurement excludes hood, projecting knobs, handles and switches]
  - (b) x - (d) x - (h) cm



    For further information about GelViu series please visit

    Accessories




GelViu series Gel Doc
With eight 8 W UVA tubes for viewing agarose gels.