| Model |
No. of wells / comb(in ready-to-use system) |
Max no. of wells/ comb available(Check table below) |
Gel size(w x l) cm |
Max. no. of combs / gel |
Buffer requirement |
For DNA and Protein separation |
For RNA separation |
With cooling and buffer circulation |
Recommended power supply |
| SLEEKSUB |
10 |
20 |
7 x 5 |
2 |
270 mL |
Yes |
No |
No |
ELECTRAGEL - 100 300V, 100mA |
| 7 x 10* |
4 |
| 7 x 15 |
6 |
| SLEEKSUB-R |
10 |
20 |
7 x 5 |
2 |
270 mL |
Yes |
Yes |
No |
ELECTRAGEL - 100 300V, 100mA |
| 7 x 10* |
4 |
| 7 x 15 |
6 |
Trays marked with an * are supplied as part of the ready-to-use system
|
| Model |
No. of wells / comb(in ready-to-use system) |
Max no. of wells/ comb available(Check table below) |
Gel size(w x l) cm |
Max. no. of combs / gel |
Buffer requirement |
For DNA and Protein separation |
For RNA separation |
With cooling and buffer circulation |
Recommended power supply |
| GELMARINER |
15 |
30 |
10 x 5 |
2 |
400 mL |
Yes |
No |
No |
ELECTRAPRIME 300V, 400mA |
| 10 x 10 |
4 |
| 10 x 15* |
6 |
| 10 x 20 |
8 |
| GELMARINER-R |
15 |
30 |
10 x 5 |
2 |
400 mL |
Yes |
Yes |
No |
ELECTRAPRIME 300V, 400mA |
| 10 x 10 |
4 |
| 10 x 15* |
6 |
| 10 x 20 |
8 |
| GELMARINER-RC |
15 |
30 |
10 x 5 |
2 |
400 mL |
Yes |
Yes |
Yes |
ELECTRAPRIME 300V, 400mA |
| 10 x 10 |
4 |
| 10 x 15* |
6 |
| 10 x 20 |
8 |
Trays marked with an * are supplied as part of the ready-to-use system
|
| Model |
No. of wells / comb(in ready-to-use system) |
Max no. of wells/ comb available(Check table below) |
Gel size(w x l) cm |
Max. no. of combs / gel |
Buffer requirement |
For DNA and Protein separation |
For RNA separation |
With cooling and buffer circulation |
Recommended power supply |
| GREYHOUND |
24 |
45 |
15 x 5 |
2 |
1000 mL |
Yes |
No |
No |
ELECTRAPRIME 300V, 400mA |
| 15 x 10 |
4 |
| 15 x 15 |
6 |
| 15 x 20* |
8 |
| 15 x 25 |
10 |
| GREYHOUND-R |
24 |
45 |
15 x 5 |
2 |
1000 mL |
Yes |
Yes |
No |
ELECTRAPRIME 300V, 400mA |
| 15 x 10 |
4 |
| 15 x 15 |
8 |
| 15 x 20* |
8 |
| 15 x 25 |
10 |
| GREYHOUND-RC |
24 |
45 |
15 x 5 |
2 |
1000 mL |
Yes |
Yes |
Yes |
ELECTRAPRIME 300V, 400mA |
| 15 x 10 |
4 |
| 15 x 15 |
8 |
| 15 x 20* |
8 |
| 15 x 25 |
10 |
| GREYHOUND-mini |
24 |
45 |
15 x 5 |
2 |
900 mL |
Yes |
No |
No |
ELECTRAPRIME 300V, 400mA |
| 15 x 10 |
4 |
Trays marked with an * are supplied as part of the ready-to-use system
|
| Model |
No. of wells / comb(in ready-to-use system) |
Max no. of wells/ comb available(Check table below) |
Gel size(w x l) cm |
Max. no. of combs / gel |
Buffer requirement |
For DNA and Protein separation |
For RNA separation |
With cooling and buffer circulation |
Recommended power supply |
| AQUAMARINER |
32 |
60 |
20 x 5 |
2 |
1200 mL |
Yes |
No |
No |
ELECTRAPRIME 300V, 400mA |
| 20 x 10 |
4 |
| 20 x 15 |
6 |
| 20 x 20* |
8 |
| AQUAMARINER-R |
32 |
60 |
20 x 5 |
2 |
1200 mL |
Yes |
Yes |
No |
ELECTRAPRIME 300V, 400mA |
| 20 x 10 |
4 |
| 20 x 15 |
8 |
| 20 x 20* |
8 |
| AQUAMARINER-RC |
32 |
60 |
20 x 5 |
2 |
1200 mL |
Yes |
Yes |
Yes |
ELECTRAPRIME 300V, 400mA |
| 20 x 10 |
4 |
| 20 x 15 |
8 |
| 20 x 20* |
8 |
| AQUAMARINER-mini |
32 |
60 |
20 x 5 |
2 |
1000 mL |
Yes |
No |
No |
ELECTRAPRIME 300V, 400mA |
| 20 x 10 |
4 |
Trays marked with an * are supplied as part of the ready-to-use system
|
| Model |
No. of wells / comb(in ready-to-use system) |
Max no. of wells/ comb available(Check table below) |
Gel size(w x l) cm |
Max. no. of combs / gel |
Buffer requirement |
For DNA and Protein separation |
For RNA separation |
With cooling and buffer circulation |
Recommended power supply |
| SUBMARINER |
36 |
70 |
23 x 5 |
2 |
1800 mL |
Yes |
No |
No |
ELECTRACOMET 200V, 500mA |
| 23 x 10 |
4 |
| 23 x 15 |
6 |
| 23 x 20* |
8 |
| 23 x 25 |
11 |
| SUBMARINER-R |
36 |
70 |
23 x 5 |
2 |
1800 mL |
Yes |
Yes |
No |
ELECTRACOMET 200V, 500mA |
| 23 x 10 |
4 |
| 23 x 15 |
6 |
| 23 x 20* |
8 |
| 23 x 25 |
11 |
| SUBMARINER-RC |
36 |
70 |
23 x 5 |
2 |
1800 mL |
Yes |
Yes |
Yes |
ELECTRACOMET 200V, 500mA |
| 23 x 10 |
4 |
| 23 x 15 |
6 |
| 23 x 20* |
8 |
| 23 x 25 |
11 |
| SUBMARINER-mini |
36 |
70 |
23 x 5 |
2 |
1500 mL |
Yes |
No |
No |
ELECTRACOMET 200V, 500mA |
| 23 x 10 |
4 |
| 23 x 15 |
6 |
Trays marked with an * are supplied as part of the ready-to-use system
|
| Model |
No. of wells / comb(in ready-to-use system) |
Max no. of wells/ comb available(Check table below) |
Gel size(w x l) cm |
Max. no. of combs / gel |
Buffer requirement |
For DNA and Protein separation |
For RNA separation |
With cooling and buffer circulation |
Recommended power supply |
| GREYWHALE-R |
54 |
92 |
30 x 5 |
2 |
2200 mL |
Yes |
Yes |
No |
ELECTRACOMET 200V, 500mA |
| 30 x 10 |
4 |
| 30 x 15 |
6 |
| 30 x 20 |
8 |
| 30 x 25 |
10 |
| 30 x 30* |
14 |
| GREYWHALE-RC |
54 |
92 |
30 x 5 |
2 |
2200 mL |
Yes |
Yes |
Yes |
ELECTRACOMET 200V, 500mA |
| 30 x 10 |
4 |
| 30 x 15 |
6 |
| 30 x 20 |
8 |
| 30 x 25 |
10 |
| 30 x 30* |
14 |
| GREYWHALE-mini |
54 |
92 |
30 x 5 |
2 |
2000 mL |
Yes |
Yes |
No |
ELECTRACOMET 200V, 500mA |
| 30 x 10 |
4 |
| 30 x 15 |
6 |
Trays marked with an * are supplied as part of the ready-to-use system
|
| LigoGel |
4 |
4 |
2.8 x 8.5 |
1 |
NA |
Yes |
Yes |
NA |
NA |
Refer to Komet for single cell electrophoresis in the
Special Equipment section